RM Analyzer Help

Action: PrDinSLc/PrDinSSup

PrDinSLc/PrDinSSup Calculates a principal tensile stresses according DIN standard for serviceability state for certain envelope or load case.

SettingDescription
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Command This is automatically assigned from the previous selection - it can not be edited in this pad.
Load case/Superposition file Name of the envelope (superposition file), or load case name, for which the check will be done
RMSET Name of RMSET, where certain additional information have to be defined

RMSET has to use certain keywords:

Key PRDIN
Inp1 Material name(without group) - f.ex. B_35
Inp2

SERVICE (Limits for service state)

REIN (Limits for dimensioning)

Inp3 SIG1..... Limits for main tensile stress

SIG2..... Limits for main pressure stress

then

....Q.....Limit  for main stress, caused by shear

....T.....Limit  for main stress, caused by torsion

....QT....Limit  for main stress, caused by shear+torsion

......FL..Limit  for web (plates)

Following combinations are possible:

SIG1Q, SIG1T, SIG1QT, SIG1QFL, SIG1TFL, SIG1QTFL SIG2Q, SIG2T, SIG2QT, SIG2QFL, SIG2TFL, SIG2QTFL

Inp4 Stress limit - f.ex. 2200

Example:

"PRDIN"    "B_35"    "SERVICE"    "SIG1Q"    "2200"
List File Name of list file, where the principal tensile stresses will be stored.
  • -If the default '*' is accepted, the name of the list file is set automatically prds0001.lst if the load case name is 1, prdsnormal.lst,  if the superposition file is normal.sup.
  • -If there is no input, no list file will be created!
Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)